Technical specifications

Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Number of poles4
Number of auxiliary contacts as normally closed contact0
With under voltage releaseNo
Overload release current setting28.0 - 40A
Type of electrical connection of main circuitBolt connection
Motor drive optionalYes
Rated voltage220 - 690V
Integrated earth fault protectionNo
Complete device with protection unitYes
With switched-off indicatorNo
Type of control elementToggle
Adjustment range undelayed short-circuit release300 - 400A
Adjustment range short-term delayed short-circuit release- - -A
Device constructionBuilt-in device fixed built-in technique
Degree of protection (IP)IP20
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068350R1 | XT4H 160 TMA 40-400 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Number of poles

4

Number of auxiliary contacts as normally closed contact

0

With under voltage release

Overload release current setting

28.0 .. 40A

Type of electrical connection of main circuit

Bolt connection

Motor drive optional

Rated voltage

220 .. 690V

Integrated earth fault protection

Complete device with protection unit

With switched-off indicator

Type of control element

Toggle

Adjustment range undelayed short-circuit release

300 .. 400A

Adjustment range short-term delayed short-circuit release

- .. -A

Device construction

Built-in device fixed built-in technique

Degree of protection (IP)

IP20

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Motor drive integrated