Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu250A
Rated voltage220 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Adjustment range undelayed short-circuit release1250 - 2500A
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionNo
Overload release current setting175.0 - 250A
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Number of poles4
Motor drive integratedNo
Position of connection for main current circuitFront side
Type of control elementToggle
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Degree of protection (IP)IP20
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068364R1 | XT4H 250 TMA 250-2500 4P F F INN=100%

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

250A

Rated voltage

220 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Adjustment range undelayed short-circuit release

1250 .. 2500A

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Overload release current setting

175.0 .. 250A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Number of poles

4

Motor drive integrated

Position of connection for main current circuit

Front side

Type of control element

Toggle

DIN rail (top hat rail) mounting optional

Motor drive optional

Degree of protection (IP)

IP20

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

With under voltage release