Technical specifications

Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact0
Number of poles3
Number of auxiliary contacts as normally open contact0
Overload release current setting28.0 - 40A
Rated voltage220 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
Motor drive integratedNo
Type of control elementToggle
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release300 - 400A
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP20
Motor drive optionalYes
Adjustment range short-term delayed short-circuit release- - -A
Position of connection for main current circuitFront side
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068369R1 | XT4L 160 TMA 40-400 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Overload release current setting

28.0 .. 40A

Rated voltage

220 .. 690V

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

Motor drive integrated

Type of control element

Toggle

Integrated earth fault protection

Adjustment range undelayed short-circuit release

300 .. 400A

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP20

Motor drive optional

Adjustment range short-term delayed short-circuit release

- .. -A

Position of connection for main current circuit

Front side

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Complete device with protection unit

DIN rail (top hat rail) mounting optional

With under voltage release