Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Complete device with protection unitYes
Rated permanent current Iu160A
Degree of protection (IP)IP20
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Motor drive integratedNo
Number of poles3
Motor drive optionalYes
Adjustment range undelayed short-circuit release300 - 500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Device constructionBuilt-in device fixed built-in technique
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release- - -A
Rated voltage220 - 690V
With under voltage releaseNo
Overload release current setting35.0 - 50A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068370R1 | XT4L 160 TMA 50-500 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Complete device with protection unit

Rated permanent current Iu

160A

Degree of protection (IP)

IP20

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Motor drive integrated

Number of poles

3

Motor drive optional

Adjustment range undelayed short-circuit release

300 .. 500A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Device construction

Built-in device fixed built-in technique

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

- .. -A

Rated voltage

220 .. 690V

With under voltage release

Overload release current setting

35.0 .. 50A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.