Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting70.0 - 100A
Rated voltage220 - 690V
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Number of poles3
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release- - -A
With switched-off indicatorNo
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Adjustment range undelayed short-circuit release500 - 1000A
Type of control elementToggle
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
With under voltage releaseNo
Motor drive optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068373R1 | XT4L 160 TMA 100-1000 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

70.0 .. 100A

Rated voltage

220 .. 690V

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Number of poles

3

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

- .. -A

With switched-off indicator

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

500 .. 1000A

Type of control element

Toggle

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

With under voltage release

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.