Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Type of control elementToggle
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Number of poles3
Rated voltage220 - 690V
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
Rated permanent current Iu250A
Degree of protection (IP)IP20
Overload release current setting140.0 - 200A
Adjustment range short-term delayed short-circuit release- - -A
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release1000 - 2000A
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068376R1 | XT4L 250 TMA 200-2000 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Type of control element

Toggle

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Rated voltage

220 .. 690V

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

Rated permanent current Iu

250A

Degree of protection (IP)

IP20

Overload release current setting

140.0 .. 200A

Adjustment range short-term delayed short-circuit release

- .. -A

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Adjustment range undelayed short-circuit release

1000 .. 2000A

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Motor drive optional

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.