1SDA068392R1 | XT4L 250 TMA 250-2500 4P F F INN=50%

Code: 1530790

ManufacturerABB
Catalog number1SDA068392R1
EAN code8015644022983

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu250A
Type of electrical connection of main circuitBolt connection
Rated voltage220 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Position of connection for main current circuitFront side
With under voltage releaseNo
Type of control elementToggle
Motor drive optionalYes
Degree of protection (IP)IP20
Motor drive integratedNo
Overload release current setting175.0 - 250A
Adjustment range undelayed short-circuit release1250 - 2500A
Number of poles4
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068392R1 | XT4L 250 TMA 250-2500 4P F F INN=50%

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

250A

Type of electrical connection of main circuit

Bolt connection

Rated voltage

220 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

With under voltage release

Type of control element

Toggle

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

Overload release current setting

175.0 .. 250A

Adjustment range undelayed short-circuit release

1250 .. 2500A

Number of poles

4

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Complete device with protection unit