Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of poles3
With switched-off indicatorNo
Adjustment range undelayed short-circuit release100 - 200A
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitFront side
Overload release current setting- - -A
Motor drive optionalYes
Number of auxiliary contacts as normally closed contact0
Rated voltage220 - 690V
Adjustment range short-term delayed short-circuit release- - -A
Degree of protection (IP)IP20
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Integrated earth fault protectionNo
Complete device with protection unitYes
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068433R1 | XT4S 160 MA 20 IM=100...200 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of poles

3

With switched-off indicator

Adjustment range undelayed short-circuit release

100 .. 200A

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Front side

Overload release current setting

- .. -A

Motor drive optional

Number of auxiliary contacts as normally closed contact

0

Rated voltage

220 .. 690V

Adjustment range short-term delayed short-circuit release

- .. -A

Degree of protection (IP)

IP20

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Integrated earth fault protection

Complete device with protection unit

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.