Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Degree of protection (IP)IP20
Rated voltage220 - 690V
Number of auxiliary contacts as change-over contact0
Overload release current setting- - -A
Number of poles3
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Integrated earth fault protectionNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release- - -A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release800 - 1600A
Position of connection for main current circuitFront side
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068439R1 | XT4S 160 MA 160 IM=800...1600 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

Number of auxiliary contacts as change-over contact

0

Overload release current setting

- .. -A

Number of poles

3

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Motor drive optional

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Integrated earth fault protection

Complete device with protection unit

DIN rail (top hat rail) mounting optional

With switched-off indicator

Adjustment range short-term delayed short-circuit release

- .. -A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

800 .. 1600A

Position of connection for main current circuit

Front side

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.