Technical specifications

Number of poles3
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Overload release current setting- - -A
Number of auxiliary contacts as change-over contact0
Rated voltage220 - 690V
Position of connection for main current circuitFront side
With switched-off indicatorNo
Motor drive integratedNo
Adjustment range undelayed short-circuit release625 - 1250A
With under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Type of control elementToggle
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release- - -A
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068458R1 | XT4L 160 MA 125 IM=625...1250 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Overload release current setting

- .. -A

Number of auxiliary contacts as change-over contact

0

Rated voltage

220 .. 690V

Position of connection for main current circuit

Front side

With switched-off indicator

Motor drive integrated

Adjustment range undelayed short-circuit release

625 .. 1250A

With under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Type of control element

Toggle

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

- .. -A

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.