Aleta.hr
Main Product Image

1SDA068490R1 | XT4S 250 EKIP LSIG IN=250A 3P F F

Code: 1530888

ManufacturerABB
Catalog number1SDA068490R1
EAN code8015644023966

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting100.0 - 250A
Rated permanent current Iu250A
Rated voltage220 - 690V
Adjustment range short-term delayed short-circuit release250 - 2500A
Adjustment range undelayed short-circuit release250 - 2500A
Integrated earth fault protectionYes
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
Number of poles3
Type of control elementToggle
Motor drive integratedNo
Position of connection for main current circuitFront side
With under voltage releaseNo
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Degree of protection (IP)IP20
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068490R1 | XT4S 250 EKIP LSIG IN=250A 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

100.0 .. 250A

Rated permanent current Iu

250A

Rated voltage

220 .. 690V

Adjustment range short-term delayed short-circuit release

250 .. 2500A

Adjustment range undelayed short-circuit release

250 .. 2500A

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

Number of poles

3

Type of control element

Toggle

Motor drive integrated

Position of connection for main current circuit

Front side

With under voltage release

Motor drive optional

DIN rail (top hat rail) mounting optional

With switched-off indicator

Degree of protection (IP)

IP20

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA