Technical specifications

Overload release current setting- - -A
Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Integrated earth fault protectionNo
Rated voltage220 - 690V
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release40 - 400A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Position of connection for main current circuitFront side
Number of poles4
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Degree of protection (IP)IP20
Type of control elementToggle
Complete device with protection unitYes
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068496R1 | XT4S 160 EKIP I IN=40A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Integrated earth fault protection

Rated voltage

220 .. 690V

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

40 .. 400A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Position of connection for main current circuit

Front side

Number of poles

4

With switched-off indicator

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

With under voltage release

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Degree of protection (IP)

IP20

Type of control element

Toggle

Complete device with protection unit

Motor drive integrated