Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Overload release current setting40.0 - 100A
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release100 - 1000A
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Degree of protection (IP)IP20
DIN rail (top hat rail) mounting optionalYes
Rated voltage220 - 690V
Adjustment range undelayed short-circuit release100 - 1000A
Type of control elementToggle
With switched-off indicatorNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Number of poles3
Integrated earth fault protectionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068528R1 | XT4H 160 EKIP LSIG IN=100A 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Overload release current setting

40.0 .. 100A

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

100 .. 1000A

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Degree of protection (IP)

IP20

DIN rail (top hat rail) mounting optional

Rated voltage

220 .. 690V

Adjustment range undelayed short-circuit release

100 .. 1000A

Type of control element

Toggle

With switched-off indicator

Motor drive optional

Position of connection for main current circuit

Front side

Number of poles

3

Integrated earth fault protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.