Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Overload release current setting100.0 - 250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Rated permanent current Iu250A
Rated voltage220 - 690V
Position of connection for main current circuitFront side
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Number of poles4
Motor drive integratedNo
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Motor drive optionalYes
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release250 - 2500A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release250 - 2500A
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068535R1 | XT4H 250 EKIP LS/I IN=250A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Overload release current setting

100.0 .. 250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Rated permanent current Iu

250A

Rated voltage

220 .. 690V

Position of connection for main current circuit

Front side

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Number of poles

4

Motor drive integrated

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Motor drive optional

Integrated earth fault protection

Adjustment range undelayed short-circuit release

250 .. 2500A

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

250 .. 2500A

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.