Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of poles4
Number of auxiliary contacts as change-over contact0
Overload release current setting64.0 - 160A
Rated permanent current Iu160A
Degree of protection (IP)IP20
Rated voltage220 - 690V
Motor drive integratedNo
Position of connection for main current circuitFront side
Type of electrical connection of main circuitBolt connection
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Adjustment range short-term delayed short-circuit release160 - 1600A
With switched-off indicatorNo
Complete device with protection unitYes
With under voltage releaseNo
Adjustment range undelayed short-circuit release160 - 1600A
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068544R1 | XT4H 160 EKIP LSI IN=160A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Overload release current setting

64.0 .. 160A

Rated permanent current Iu

160A

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

Motor drive integrated

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Bolt connection

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Adjustment range short-term delayed short-circuit release

160 .. 1600A

With switched-off indicator

Complete device with protection unit

With under voltage release

Adjustment range undelayed short-circuit release

160 .. 1600A

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Motor drive optional