Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Device constructionBuilt-in device fixed built-in technique
Rated permanent current Iu250A
Degree of protection (IP)IP20
Number of poles4
Motor drive integratedNo
Rated voltage220 - 690V
Type of control elementToggle
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release250 - 2500A
Overload release current setting100.0 - 250A
Number of auxiliary contacts as normally open contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
With under voltage releaseNo
Integrated earth fault protectionNo
Motor drive optionalYes
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release250 - 2500A
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068545R1 | XT4H 250 EKIP LSI IN=250A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Device construction

Built-in device fixed built-in technique

Rated permanent current Iu

250A

Degree of protection (IP)

IP20

Number of poles

4

Motor drive integrated

Rated voltage

220 .. 690V

Type of control element

Toggle

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

250 .. 2500A

Overload release current setting

100.0 .. 250A

Number of auxiliary contacts as normally open contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

With under voltage release

Integrated earth fault protection

Motor drive optional

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

250 .. 2500A

Complete device with protection unit

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.