Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu160A
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Overload release current setting25.2 - 63A
Number of auxiliary contacts as normally open contact0
Rated voltage220 - 690V
Degree of protection (IP)IP20
Number of poles3
With switched-off indicatorNo
Motor drive integratedNo
Type of control elementToggle
Position of connection for main current circuitFront side
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Adjustment range short-term delayed short-circuit release63 - 630A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release63 - 630A
Integrated earth fault protectionNo
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068552R1 | XT4L 160 EKIP LS/I IN=63A 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

160A

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

25.2 .. 63A

Number of auxiliary contacts as normally open contact

0

Rated voltage

220 .. 690V

Degree of protection (IP)

IP20

Number of poles

3

With switched-off indicator

Motor drive integrated

Type of control element

Toggle

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Adjustment range short-term delayed short-circuit release

63 .. 630A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

63 .. 630A

Integrated earth fault protection

With under voltage release

Device construction

Built-in device fixed built-in technique

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.