Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated voltage220 - 690V
Type of electrical connection of main circuitBolt connection
Rated permanent current Iu160A
Overload release current setting25.2 - 63A
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release63 - 630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release63 - 630A
Number of poles3
With under voltage releaseNo
With switched-off indicatorNo
Type of control elementToggle
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Motor drive integratedNo
Motor drive optionalYes
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068562R1 | XT4L 160 EKIP LSI IN=63A 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated voltage

220 .. 690V

Type of electrical connection of main circuit

Bolt connection

Rated permanent current Iu

160A

Overload release current setting

25.2 .. 63A

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

63 .. 630A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Adjustment range undelayed short-circuit release

63 .. 630A

Number of poles

3

With under voltage release

With switched-off indicator

Type of control element

Toggle

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Motor drive integrated

Motor drive optional

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.