Aleta.hr
Main Product Image

1SDA068574R1 | XT4L 160 EKIP LS/I IN=160A 4P F F

Code: 1530972

ManufacturerABB
Catalog number1SDA068574R1
EAN code8015644024802

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Rated permanent current Iu160A
Adjustment range short-term delayed short-circuit release160 - 1600A
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release160 - 1600A
Rated voltage220 - 690V
With switched-off indicatorNo
Integrated earth fault protectionNo
Overload release current setting64.0 - 160A
Number of poles4
Position of connection for main current circuitFront side
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Type of control elementToggle
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP20
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068574R1 | XT4L 160 EKIP LS/I IN=160A 4P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Rated permanent current Iu

160A

Adjustment range short-term delayed short-circuit release

160 .. 1600A

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

160 .. 1600A

Rated voltage

220 .. 690V

With switched-off indicator

Integrated earth fault protection

Overload release current setting

64.0 .. 160A

Number of poles

4

Position of connection for main current circuit

Front side

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Type of control element

Toggle

Device construction

Built-in device fixed built-in technique

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP20

With under voltage release

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.