Aleta.hr
Main Product Image

1SDA068589R1 | XT4L 160 EKIP LSIG IN=160A 4P F F

Code: 1530987

ManufacturerABB
Catalog number1SDA068589R1
EAN code8015644024956

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting64.0 - 160A
Adjustment range short-term delayed short-circuit release160 - 1600A
Device constructionBuilt-in device fixed built-in technique
Rated permanent current Iu160A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Integrated earth fault protectionYes
Adjustment range undelayed short-circuit release160 - 1600A
Type of electrical connection of main circuitBolt connection
With under voltage releaseNo
Rated voltage220 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementToggle
Position of connection for main current circuitFront side
Complete device with protection unitYes
Number of poles4
Motor drive integratedNo
Motor drive optionalYes
Degree of protection (IP)IP20
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA068589R1 | XT4L 160 EKIP LSIG IN=160A 4P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

64.0 .. 160A

Adjustment range short-term delayed short-circuit release

160 .. 1600A

Device construction

Built-in device fixed built-in technique

Rated permanent current Iu

160A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Integrated earth fault protection

Adjustment range undelayed short-circuit release

160 .. 1600A

Type of electrical connection of main circuit

Bolt connection

With under voltage release

Rated voltage

220 .. 690V

Suitable for DIN rail (top hat rail) mounting

Type of control element

Toggle

Position of connection for main current circuit

Front side

Complete device with protection unit

Number of poles

4

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP20

With switched-off indicator

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.