Aleta.hr

Details

  • Low-voltage industrial components
  • Arc detection system
  • 1 KOM
  • ABB

Technical specifications

ExpandableYes
ModelModular
Mounting methodSurface mounting
Width210mm
Depth80mm
Over current protectionNo
Height230mm
Rated control supply voltage Us at AC 50HZ100 - 240V
Rated control supply voltage Us at DC100 - 240V
Rated control supply voltage Us at AC 60HZ100 - 240V
Number of contacts as normally closed contact0
Number of inputs12
Voltage type for actuatingAC/DC
Degree of protection (IP), front sideIP54
Type of electric connectionScrew connection
Number of contacts as normally open contact3
Circuit-breaker failure protection (ANSI 50BF)No
Number of phase/neutral current inputs-
Rated current of phase/neutral current inputs-A
Number of fast fibre optic signal inputs/outputs-
Number of trip outputs3
Max. number of arc sensors30
Operation trip time1ms
Number of binary inputs-
Number of contacts as change-over contact3
Number of binary outputs-
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SFA664001R1001 | ARC MONITOR TVOC-2-240

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Arc detection system
  • 1 KOM
  • ABB

Technical specifications

Expandable

Model

Modular

Mounting method

Surface mounting

Width

210mm

Depth

80mm

Over current protection

Height

230mm

Rated control supply voltage Us at AC 50HZ

100 .. 240V

Rated control supply voltage Us at DC

100 .. 240V

Rated control supply voltage Us at AC 60HZ

100 .. 240V

Number of contacts as normally closed contact

0

Number of inputs

12

Voltage type for actuating

AC/DC

Degree of protection (IP), front side

IP54

Type of electric connection

Screw connection

Number of contacts as normally open contact

3

Circuit-breaker failure protection (ANSI 50BF)

Number of phase/neutral current inputs

-

Rated current of phase/neutral current inputs

-A

Number of fast fibre optic signal inputs/outputs

-

Number of trip outputs

3

Max. number of arc sensors

30

Operation trip time

1ms

Number of binary inputs

-

Number of contacts as change-over contact

3

Number of binary outputs

-

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.