Details
- Relays
- Timer relay
- 1 KOM
- ABB
Technical specifications
Number of outputs, undelayed, normally closed contact
0
Number of outputs, undelayed, normally open contact
0
Number of outputs, delayed, normally closed contact
0
Number of outputs, delayed, normally open contact
0
Function pulse shaping
No
Function flashing, starting with pulse, fixed time
No
Function delay on de-energization
No
Type of electric connection
Screw connection
Clock function, starting with pause, variable
No
Clock function, starting with pulse, variable
No
Function star-delta
No
Function delay-on energization
Yes
Voltage type for actuating
AC/DC
Rated control supply voltage Us at AC 60HZ
24 - 240V
Number of outputs, delayed, change-over contact
2
With plug-in socket
No
Function flashing, starting with pause, fixed time
No
Rated control supply voltage Us at DC
24 - 48V
Rated control supply voltage Us at AC 50HZ
24 - 240V
Time range
0.05 - 1080000s
Number of outputs, undelayed, change-over contact
2
Height
85.6mm
Remote operation possible
No
Function floating contact on energization
No
Outputs, reversible delayed/undelayed
No
Pluggable on auxiliary contact block
No
Suitable as remote control
No
Function floating contact on de-energization
No
With semiconductor output
No
Suitable for DIN rail (top hat rail) mounting
Yes
Suitable for front mounting
No
Width
22.5mm
Depth
103.7mm
Nominal current
4A
From same serie
1SVR730100R3300 | CT-ERS.22S

Details
- Relays
- Timer relay
- 1 KOM
- ABB
Technical specifications
Number of outputs, undelayed, normally closed contact
0
Number of outputs, undelayed, normally open contact
0
Number of outputs, delayed, normally closed contact
0
Number of outputs, delayed, normally open contact
0
Function pulse shaping
Function flashing, starting with pulse, fixed time
Function delay on de-energization
Type of electric connection
Screw connection
Clock function, starting with pause, variable
Clock function, starting with pulse, variable
Function star-delta
Function delay-on energization
Voltage type for actuating
AC/DC
Rated control supply voltage Us at AC 60HZ
24 .. 240V
Number of outputs, delayed, change-over contact
2
With plug-in socket
Function flashing, starting with pause, fixed time
Rated control supply voltage Us at DC
24 .. 48V
Rated control supply voltage Us at AC 50HZ
24 .. 240V
Time range
0.05 .. 1080000s
Number of outputs, undelayed, change-over contact
2
Height
85.6mm
Remote operation possible
Function floating contact on energization
Outputs, reversible delayed/undelayed
Pluggable on auxiliary contact block
Suitable as remote control
Function floating contact on de-energization
With semiconductor output
Suitable for DIN rail (top hat rail) mounting
Suitable for front mounting
Width
22.5mm
Depth
103.7mm
Nominal current
4A