Aleta.hr
Main Product Image

1SVR730794R1300 | CM-PVS.31S

Code: 1543681

ManufacturerABB
Catalog number1SVR730794R1300
TypeRelays
EAN code4016779851831

Details

  • Relays
  • Phase monitoring relay
  • 1 KOM
  • ABB

Technical specifications

With detachable clampsNo
Voltage type for actuatingAC
Rated control supply voltage Us at AC 60HZ160 - 300V
Rated control supply voltage Us at AC 50HZ160 - 300V
Max. permitted delay-on energization time0.2s
Rated control supply voltage Us at DC- - -V
Min. adjustable delay-on energization time0.2s
Type of electric connectionScrew connection
External power supply requiredNo
Max. permitted off-delay time30s
Min. adjustable off-delay time0.1s
Voltage type (operating voltage)AC
Height85.6mm
Width22.5mm
Depth103.7mm
Voltage measuring range160 - 300V
Voltage type of supply voltageAC
Phase sequence monitoringYes
Phase failure detectionYes
Function under voltage detectionYes
Function over voltage detectionYes
Phase imbalance monitoringNo
Number of contacts as normally closed contact0
Number of contacts as normally open contact0
Number of contacts as change-over contact2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SVR730794R1300 | CM-PVS.31S

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Relays
  • Phase monitoring relay
  • 1 KOM
  • ABB

Technical specifications

With detachable clamps

Voltage type for actuating

AC

Rated control supply voltage Us at AC 60HZ

160 .. 300V

Rated control supply voltage Us at AC 50HZ

160 .. 300V

Max. permitted delay-on energization time

0.2s

Rated control supply voltage Us at DC

- .. -V

Min. adjustable delay-on energization time

0.2s

Type of electric connection

Screw connection

External power supply required

Max. permitted off-delay time

30s

Min. adjustable off-delay time

0.1s

Voltage type (operating voltage)

AC

Height

85.6mm

Width

22.5mm

Depth

103.7mm

Voltage measuring range

160 .. 300V

Voltage type of supply voltage

AC

Phase sequence monitoring

Phase failure detection

Function under voltage detection

Function over voltage detection

Phase imbalance monitoring

Number of contacts as normally closed contact

0

Number of contacts as normally open contact

0

Number of contacts as change-over contact

2