Aleta.hr
Main Product Image

1SVR740794R2300 | CM-PVS.81P

Code: 1543748

ManufacturerABB
Catalog number1SVR740794R2300
TypeRelays
EAN code4016779876490

Details

  • Relays
  • Phase monitoring relay
  • 1 KOM
  • ABB

Technical specifications

Height85.6mm
Rated control supply voltage Us at DC- - -V
Rated control supply voltage Us at AC 60HZ200 - 400V
Phase imbalance monitoringNo
Depth103.7mm
Rated control supply voltage Us at AC 50HZ200 - 400V
Min. adjustable delay-on energization time0.2s
Max. permitted delay-on energization time0.2s
With detachable clampsNo
Max. permitted off-delay time30s
Voltage measuring range200 - 400V
Number of contacts as normally closed contact-
Voltage type for actuatingAC
Min. adjustable off-delay time0.1s
Number of contacts as normally open contact-
External power supply requiredNo
Type of electric connectionSpring clamp connection
Function under voltage detectionYes
Phase sequence monitoringYes
Function over voltage detectionYes
Voltage type (operating voltage)AC
Voltage type of supply voltageAC
Width22.5mm
Phase failure detectionYes
Number of contacts as change-over contact2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SVR740794R2300 | CM-PVS.81P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Relays
  • Phase monitoring relay
  • 1 KOM
  • ABB

Technical specifications

Height

85.6mm

Rated control supply voltage Us at DC

- .. -V

Rated control supply voltage Us at AC 60HZ

200 .. 400V

Phase imbalance monitoring

Depth

103.7mm

Rated control supply voltage Us at AC 50HZ

200 .. 400V

Min. adjustable delay-on energization time

0.2s

Max. permitted delay-on energization time

0.2s

With detachable clamps

Max. permitted off-delay time

30s

Voltage measuring range

200 .. 400V

Number of contacts as normally closed contact

-

Voltage type for actuating

AC

Min. adjustable off-delay time

0.1s

Number of contacts as normally open contact

-

External power supply required

Type of electric connection

Spring clamp connection

Function under voltage detection

Phase sequence monitoring

Function over voltage detection

Voltage type (operating voltage)

AC

Voltage type of supply voltage

AC

Width

22.5mm

Phase failure detection

Number of contacts as change-over contact

2