Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP20
Voltage typeDC
Suitable for flush-mounted installationNo
Built-in depth82.5mm
Rated voltage800V
Rated current16A
Width in number of modular spacings2
Release characteristicB
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Number of protected poles2
Rated impulse withstand voltage Uimp8kV
Number of poles (total)2
Rated insulation voltage Ui1500V
Current limiting class-
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V5kA
FrequencyHz
Ambient temperature during operating-25 - 60°C
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V5kA
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Power loss6.2W
Explosion-proofNo
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCP842001R1169 | S802PV-S16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

DC

Suitable for flush-mounted installation

Built-in depth

82.5mm

Rated voltage

800V

Rated current

16A

Width in number of modular spacings

2

Release characteristic

B

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Number of protected poles

2

Rated impulse withstand voltage Uimp

8kV

Number of poles (total)

2

Rated insulation voltage Ui

1500V

Current limiting class

-

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

5kA

Frequency

Hz

Ambient temperature during operating

-25 .. 60°C

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

5kA

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

6.2W

Explosion-proof

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.