  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP20
Voltage typeDC
Suitable for flush-mounted installationNo
Built-in depth82.5mm
Rated voltage1200V
Rated current10A
Width in number of modular spacings3
Release characteristicB
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V5kA
Number of protected poles3
Rated impulse withstand voltage Uimp8kV
Number of poles (total)3
Rated insulation voltage Ui1500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V5kA
Current limiting class-
Additional equipment possibleYes
FrequencyHz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Ambient temperature during operating-25 - 60°C
Pollution degree2
Concurrently switching neutral conductorNo
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Power loss4.5W
Flush-mounted installationNo
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCP843001R1109 | S803PV-S10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

DC

Suitable for flush-mounted installation

Built-in depth

82.5mm

Rated voltage

1200V

Rated current

10A

Width in number of modular spacings

3

Release characteristic

B

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

5kA

Number of protected poles

3

Rated impulse withstand voltage Uimp

8kV

Number of poles (total)

3

Rated insulation voltage Ui

1500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

5kA

Current limiting class

-

Additional equipment possible

Frequency

Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Ambient temperature during operating

-25 .. 60°C

Pollution degree

2

Concurrently switching neutral conductor

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

4.5W

Flush-mounted installation

Explosion-proof