  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Rated current6A
Voltage typeAC
Rated voltage400V
Frequency50 - 60Hz
Release characteristicD
Current limiting class3
Rated insulation voltage Ui690V
Number of protected poles1
Degree of protection (IP)IP20
Width in number of modular spacings1
Over voltage category3
Pollution degree3
Connectable conductor cross section multi-wired0 - 70mm²
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Number of poles (total)1
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R0061 | S801S-D6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated current

6A

Voltage type

AC

Rated voltage

400V

Frequency

50 .. 60Hz

Release characteristic

D

Current limiting class

3

Rated insulation voltage Ui

690V

Number of protected poles

1

Degree of protection (IP)

IP20

Width in number of modular spacings

1

Over voltage category

3

Pollution degree

3

Connectable conductor cross section multi-wired

0 .. 70mm²

Additional equipment possible

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Number of poles (total)

1

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.