Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Built-in depth82.5mm
Rated current6A
Release characteristicB
Frequency50 - 60Hz
Current limiting class3
Over voltage category3
Rated insulation voltage Ui690V
Rated voltage400V
Number of protected poles1
Degree of protection (IP)IP20
Pollution degree3
Width in number of modular spacings1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Number of poles (total)1
Connectable conductor cross section multi-wired0 - 70mm²
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R0065 | S801S-B6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Built-in depth

82.5mm

Rated current

6A

Release characteristic

B

Frequency

50 .. 60Hz

Current limiting class

3

Over voltage category

3

Rated insulation voltage Ui

690V

Rated voltage

400V

Number of protected poles

1

Degree of protection (IP)

IP20

Pollution degree

3

Width in number of modular spacings

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Number of poles (total)

1

Connectable conductor cross section multi-wired

0 .. 70mm²

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.