Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current6A
Over voltage category3
Rated voltage400V
Built-in depth82.5mm
Concurrently switching neutral conductorNo
Number of protected poles1
Release characteristicK
Pollution degree3
Degree of protection (IP)IP20
Width in number of modular spacings1
Rated insulation voltage Ui690V
Current limiting class3
Frequency50 - 60Hz
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Connectable conductor cross section solid-core0 - 50mm²
Number of poles (total)1
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R0067 | S801S-K6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

6A

Over voltage category

3

Rated voltage

400V

Built-in depth

82.5mm

Concurrently switching neutral conductor

Number of protected poles

1

Release characteristic

K

Pollution degree

3

Degree of protection (IP)

IP20

Width in number of modular spacings

1

Rated insulation voltage Ui

690V

Current limiting class

3

Frequency

50 .. 60Hz

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Connectable conductor cross section solid-core

0 .. 50mm²

Number of poles (total)

1

Additional equipment possible

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.