Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Rated current16A
Release characteristicB
Built-in depth82.5mm
Frequency50 - 60Hz
Rated insulation voltage Ui690V
Voltage typeAC
Over voltage category3
Current limiting class3
Pollution degree3
Number of protected poles1
Additional equipment possibleYes
Number of poles (total)1
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Width in number of modular spacings1
Suitable for flush-mounted installationNo
Rated impulse withstand voltage Uimp8kV
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R0165 | S801S-B16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Rated current

16A

Release characteristic

B

Built-in depth

82.5mm

Frequency

50 .. 60Hz

Rated insulation voltage Ui

690V

Voltage type

AC

Over voltage category

3

Current limiting class

3

Pollution degree

3

Number of protected poles

1

Additional equipment possible

Number of poles (total)

1

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Width in number of modular spacings

1

Suitable for flush-mounted installation

Rated impulse withstand voltage Uimp

8kV

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.