Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui690V
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Number of poles (total)1
Rated current20A
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Release characteristicD
Current limiting class3
Rated impulse withstand voltage Uimp8kV
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Suitable for flush-mounted installationNo
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Additional equipment possibleYes
Built-in depth82.5mm
Ambient temperature during operating-25 - 60°C
Pollution degree3
Over voltage category3
Connectable conductor cross section multi-wired0 - 70mm²
Width in number of modular spacings1
Connectable conductor cross section solid-core0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R0201 | S801S-D20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

690V

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Number of poles (total)

1

Rated current

20A

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Release characteristic

D

Current limiting class

3

Rated impulse withstand voltage Uimp

8kV

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Suitable for flush-mounted installation

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Additional equipment possible

Built-in depth

82.5mm

Ambient temperature during operating

-25 .. 60°C

Pollution degree

3

Over voltage category

3

Connectable conductor cross section multi-wired

0 .. 70mm²

Width in number of modular spacings

1

Connectable conductor cross section solid-core

0 .. 50mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.