Technical specifications

Rated voltage400V
Frequency50 - 60Hz
Built-in depth82.5mm
Pollution degree3
Current limiting class3
Rated insulation voltage Ui690V
Width in number of modular spacings1
Over voltage category3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Connectable conductor cross section multi-wired0 - 70mm²
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated impulse withstand voltage Uimp8kV
Number of poles (total)1
Release characteristicD
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated current32A
Number of protected poles1
Voltage typeAC/DC
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R0321 | S801S-D32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Pollution degree

3

Current limiting class

3

Rated insulation voltage Ui

690V

Width in number of modular spacings

1

Over voltage category

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

8kV

Number of poles (total)

1

Release characteristic

D

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated current

32A

Number of protected poles

1

Voltage type

AC/DC

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.