Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Rated insulation voltage Ui690V
Current limiting class3
Frequency50 - 60Hz
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Pollution degree3
Suitable for flush-mounted installationNo
Rated voltage400V
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Connectable conductor cross section multi-wired0 - 70mm²
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp8kV
Voltage typeAC/DC
Rated current16A
Release characteristicK
Width in number of modular spacings1.5
Number of protected poles1
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R0467 | S801S-K16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated insulation voltage Ui

690V

Current limiting class

3

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Pollution degree

3

Suitable for flush-mounted installation

Rated voltage

400V

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

8kV

Voltage type

AC/DC

Rated current

16A

Release characteristic

K

Width in number of modular spacings

1.5

Number of protected poles

1

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.