Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

FrequencyHz
Release characteristicB
Rated insulation voltage Ui1000V
Suitable for flush-mounted installationNo
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Voltage typeDC
Width in number of modular spacings1
Number of protected poles1
Rated voltage250V
Additional equipment possibleYes
Over voltage category3
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Built-in depth82.5mm
Number of poles (total)1
Ambient temperature during operating-25 - 60°C
Rated current13A
Current limiting class3
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 50mm²
Connectable conductor cross section multi-wired0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R1135 | S801S-UCB13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

Hz

Release characteristic

B

Rated insulation voltage Ui

1000V

Suitable for flush-mounted installation

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Voltage type

DC

Width in number of modular spacings

1

Number of protected poles

1

Rated voltage

250V

Additional equipment possible

Over voltage category

3

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Built-in depth

82.5mm

Number of poles (total)

1

Ambient temperature during operating

-25 .. 60°C

Rated current

13A

Current limiting class

3

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 50mm²

Connectable conductor cross section multi-wired

0 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.