Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Connectable conductor cross section solid-core0 - 50mm²
Width in number of modular spacings1
Rated voltage250V
Degree of protection (IP)IP20
Rated current13A
Number of protected poles1
Pollution degree2
Concurrently switching neutral conductorNo
Release characteristicB
FrequencyHz
Current limiting class3
Rated insulation voltage Ui1000V
Voltage typeDC
Over voltage category3
Suitable for flush-mounted installationNo
Built-in depth82.5mm
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section multi-wired0 - 70mm²
Rated impulse withstand voltage Uimp8kV
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R1135 | S801S-UCB13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Connectable conductor cross section solid-core

0 .. 50mm²

Width in number of modular spacings

1

Rated voltage

250V

Degree of protection (IP)

IP20

Rated current

13A

Number of protected poles

1

Pollution degree

2

Concurrently switching neutral conductor

Release characteristic

B

Frequency

Hz

Current limiting class

3

Rated insulation voltage Ui

1000V

Voltage type

DC

Over voltage category

3

Suitable for flush-mounted installation

Built-in depth

82.5mm

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated impulse withstand voltage Uimp

8kV

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.