Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

FrequencyHz
Number of poles (total)1
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Rated impulse withstand voltage Uimp8kV
Rated current20A
Concurrently switching neutral conductorNo
Rated insulation voltage Ui1000V
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Width in number of modular spacings1
Rated voltage250V
Suitable for flush-mounted installationNo
Pollution degree2
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Additional equipment possibleYes
Over voltage category3
Release characteristicB
Voltage typeDC
Built-in depth82.5mm
Connectable conductor cross section solid-core0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R1205 | S801S-UCB20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

Hz

Number of poles (total)

1

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Rated impulse withstand voltage Uimp

8kV

Rated current

20A

Concurrently switching neutral conductor

Rated insulation voltage Ui

1000V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Width in number of modular spacings

1

Rated voltage

250V

Suitable for flush-mounted installation

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Additional equipment possible

Over voltage category

3

Release characteristic

B

Voltage type

DC

Built-in depth

82.5mm

Connectable conductor cross section solid-core

0 .. 50mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.