Built-in depth82.5mm
Number of protected poles1
Current limiting class3
Degree of protection (IP)IP20
Release characteristicB
FrequencyHz
Width in number of modular spacings1
Pollution degree2
Rated current40A
Rated insulation voltage Ui1000V
Rated voltage250V
Connectable conductor cross section solid-core0 - 50mm²
Concurrently switching neutral conductorNo
Over voltage category3
Suitable for flush-mounted installationNo
Voltage typeDC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Number of poles (total)1
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 70mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R1405 | S801S-UCB40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Number of protected poles

1

Current limiting class

3

Degree of protection (IP)

IP20

Release characteristic

B

Frequency

Hz

Width in number of modular spacings

1

Pollution degree

2

Rated current

40A

Rated insulation voltage Ui

1000V

Rated voltage

250V

Connectable conductor cross section solid-core

0 .. 50mm²

Concurrently switching neutral conductor

Over voltage category

3

Suitable for flush-mounted installation

Voltage type

DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of poles (total)

1

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 70mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA