Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

FrequencyHz
Rated voltage250V
Rated current20A
Voltage typeDC
Built-in depth82.5mm
Current limiting class3
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Release characteristicK
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Pollution degree2
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Number of poles (total)1
Number of protected poles1
Width in number of modular spacings1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 70mm²
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Degree of protection (IP)IP20
Rated insulation voltage Ui1000V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R1487 | S801S-UCK20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

Hz

Rated voltage

250V

Rated current

20A

Voltage type

DC

Built-in depth

82.5mm

Current limiting class

3

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Release characteristic

K

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Pollution degree

2

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Number of poles (total)

1

Number of protected poles

1

Width in number of modular spacings

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Degree of protection (IP)

IP20

Rated insulation voltage Ui

1000V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.