  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeDC
Rated voltage250V
Rated current32A
Over voltage category3
FrequencyHz
Current limiting class3
Number of protected poles1
Width in number of modular spacings1
Degree of protection (IP)IP20
Pollution degree2
Built-in depth82.5mm
Release characteristicK
Concurrently switching neutral conductorNo
Rated insulation voltage Ui1000V
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Additional equipment possibleYes
Number of poles (total)1
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Ambient temperature during operating-25 - 60°C
Suitable for flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R1537 | S801S-UCK32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

DC

Rated voltage

250V

Rated current

32A

Over voltage category

3

Frequency

Hz

Current limiting class

3

Number of protected poles

1

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Pollution degree

2

Built-in depth

82.5mm

Release characteristic

K

Concurrently switching neutral conductor

Rated insulation voltage Ui

1000V

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Additional equipment possible

Number of poles (total)

1

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Ambient temperature during operating

-25 .. 60°C

Suitable for flush-mounted installation