Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

FrequencyHz
Number of poles (total)1
Release characteristicK
Rated current40A
Number of protected poles1
Rated insulation voltage Ui1000V
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Additional equipment possibleYes
Current limiting class3
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Built-in depth82.5mm
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0 - 70mm²
Pollution degree2
Voltage typeDC
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Width in number of modular spacings1
Connectable conductor cross section solid-core0 - 50mm²
Suitable for flush-mounted installationNo
Rated voltage250V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R1557 | S801S-UCK40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

Hz

Number of poles (total)

1

Release characteristic

K

Rated current

40A

Number of protected poles

1

Rated insulation voltage Ui

1000V

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Additional equipment possible

Current limiting class

3

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Built-in depth

82.5mm

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 70mm²

Pollution degree

2

Voltage type

DC

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Width in number of modular spacings

1

Connectable conductor cross section solid-core

0 .. 50mm²

Suitable for flush-mounted installation

Rated voltage

250V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.