Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

FrequencyHz
Release characteristicK
Number of poles (total)1
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Rated insulation voltage Ui1000V
Rated voltage250V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Width in number of modular spacings1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Suitable for flush-mounted installationNo
Rated impulse withstand voltage Uimp8kV
Concurrently switching neutral conductorNo
Pollution degree2
Over voltage category3
Built-in depth82.5mm
Connectable conductor cross section multi-wired0 - 70mm²
Voltage typeDC
Degree of protection (IP)IP20
Current limiting class3
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 50mm²
Ambient temperature during operating-25 - 60°C
Rated current50A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R1577 | S801S-UCK50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

Hz

Release characteristic

K

Number of poles (total)

1

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Rated insulation voltage Ui

1000V

Rated voltage

250V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Width in number of modular spacings

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Suitable for flush-mounted installation

Rated impulse withstand voltage Uimp

8kV

Concurrently switching neutral conductor

Pollution degree

2

Over voltage category

3

Built-in depth

82.5mm

Connectable conductor cross section multi-wired

0 .. 70mm²

Voltage type

DC

Degree of protection (IP)

IP20

Current limiting class

3

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Rated current

50A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.