Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current80A
Built-in depth82.5mm
Rated voltage250V
Voltage typeDC
Rated insulation voltage Ui1000V
Release characteristicK
Current limiting class3
FrequencyHz
Number of protected poles1
Width in number of modular spacings1
Concurrently switching neutral conductorNo
Number of poles (total)1
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 50mm²
Rated impulse withstand voltage Uimp8kV
Pollution degree2
Over voltage category3
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R1627 | S801S-UCK80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

80A

Built-in depth

82.5mm

Rated voltage

250V

Voltage type

DC

Rated insulation voltage Ui

1000V

Release characteristic

K

Current limiting class

3

Frequency

Hz

Number of protected poles

1

Width in number of modular spacings

1

Concurrently switching neutral conductor

Number of poles (total)

1

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 50mm²

Rated impulse withstand voltage Uimp

8kV

Pollution degree

2

Over voltage category

3

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.