Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

FrequencyHz
Rated insulation voltage Ui1000V
Built-in depth82.5mm
Concurrently switching neutral conductorNo
Over voltage category3
Suitable for flush-mounted installationNo
Degree of protection (IP)IP20
Current limiting class3
Width in number of modular spacings1
Pollution degree2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Rated impulse withstand voltage Uimp8kV
Number of protected poles1
Release characteristicB
Rated current80A
Number of poles (total)1
Rated voltage250V
Voltage typeDC
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R1805 | S801S-UCB80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

Hz

Rated insulation voltage Ui

1000V

Built-in depth

82.5mm

Concurrently switching neutral conductor

Over voltage category

3

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Current limiting class

3

Width in number of modular spacings

1

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Rated impulse withstand voltage Uimp

8kV

Number of protected poles

1

Release characteristic

B

Rated current

80A

Number of poles (total)

1

Rated voltage

250V

Voltage type

DC

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.