Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

FrequencyHz
Voltage typeDC
Rated insulation voltage Ui1000V
Rated voltage250V
Rated current80A
Release characteristicB
Built-in depth82.5mm
Concurrently switching neutral conductorNo
Over voltage category3
Suitable for flush-mounted installationNo
Degree of protection (IP)IP20
Current limiting class3
Width in number of modular spacings1
Number of protected poles1
Pollution degree2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V50kA
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Number of poles (total)1
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V50kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861001R1805 | S801S-UCB80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

Hz

Voltage type

DC

Rated insulation voltage Ui

1000V

Rated voltage

250V

Rated current

80A

Release characteristic

B

Built-in depth

82.5mm

Concurrently switching neutral conductor

Over voltage category

3

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Current limiting class

3

Width in number of modular spacings

1

Number of protected poles

1

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

50kA

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of poles (total)

1

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

50kA

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.