Technical specifications

Rated current6A
Built-in depth82.5mm
Degree of protection (IP)IP2X
Width in number of modular spacings3
Rated voltage400V
Rated insulation voltage Ui690V
Release characteristicB
Current limiting class3
Number of protected poles2
Pollution degree3
Voltage typeAC
Concurrently switching neutral conductorNo
Over voltage category3
Frequency50 - 60Hz
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Number of poles (total)2
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R0061 | S802S-D6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

6A

Built-in depth

82.5mm

Degree of protection (IP)

IP2X

Width in number of modular spacings

3

Rated voltage

400V

Rated insulation voltage Ui

690V

Release characteristic

B

Current limiting class

3

Number of protected poles

2

Pollution degree

3

Voltage type

AC

Concurrently switching neutral conductor

Over voltage category

3

Frequency

50 .. 60Hz

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Number of poles (total)

2

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

8kV