Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Rated voltage400V
Frequency50 - 60Hz
Over voltage category2
Rated insulation voltage Ui690V
Pollution degree3
Current limiting class3
Width in number of modular spacings2
Connectable conductor cross section solid-core0 - 50mm²
Suitable for flush-mounted installationNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp8kV
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Release characteristicK
Number of poles (total)2
Number of protected poles2
Voltage typeAC/DC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated current6A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R0067 | S802S-K6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated voltage

400V

Frequency

50 .. 60Hz

Over voltage category

2

Rated insulation voltage Ui

690V

Pollution degree

3

Current limiting class

3

Width in number of modular spacings

2

Connectable conductor cross section solid-core

0 .. 50mm²

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

8kV

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Release characteristic

K

Number of poles (total)

2

Number of protected poles

2

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated current

6A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.