Technical specifications

Rated voltage400V
Frequency50 - 60Hz
Built-in depth82.5mm
Rated current10A
Voltage typeAC
Suitable for flush-mounted installationNo
Width in number of modular spacings3
Number of protected poles2
Connectable conductor cross section solid-core0 - 50mm²
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Pollution degree3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Concurrently switching neutral conductorNo
Current limiting class3
Over voltage category3
Release characteristicD
Rated impulse withstand voltage Uimp8kV
Connectable conductor cross section multi-wired0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R0101 | S802S-D10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Rated current

10A

Voltage type

AC

Suitable for flush-mounted installation

Width in number of modular spacings

3

Number of protected poles

2

Connectable conductor cross section solid-core

0 .. 50mm²

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Pollution degree

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Concurrently switching neutral conductor

Current limiting class

3

Over voltage category

3

Release characteristic

D

Rated impulse withstand voltage Uimp

8kV

Connectable conductor cross section multi-wired

0 .. 70mm²