Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeAC
Frequency50 - 60Hz
Additional equipment possibleYes
Rated insulation voltage Ui690V
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Ambient temperature during operating-25 - 60°C
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Over voltage category3
Rated impulse withstand voltage Uimp8kV
Concurrently switching neutral conductorNo
Width in number of modular spacings3
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Pollution degree3
Release characteristicB
Number of poles (total)2
Rated current10A
Number of protected poles2
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R0105 | S802S-B10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

AC

Frequency

50 .. 60Hz

Additional equipment possible

Rated insulation voltage Ui

690V

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Ambient temperature during operating

-25 .. 60°C

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Over voltage category

3

Rated impulse withstand voltage Uimp

8kV

Concurrently switching neutral conductor

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Pollution degree

3

Release characteristic

B

Number of poles (total)

2

Rated current

10A

Number of protected poles

2

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.