Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Built-in depth82.5mm
Rated insulation voltage Ui690V
Pollution degree3
Current limiting class3
Over voltage category3
Width in number of modular spacings3
Degree of protection (IP)IP20
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Ambient temperature during operating-25 - 60°C
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp8kV
Release characteristicC
Number of poles (total)2
Number of protected poles2
Rated current16A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated voltage400V
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R0164 | S802S-C16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Rated insulation voltage Ui

690V

Pollution degree

3

Current limiting class

3

Over voltage category

3

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Ambient temperature during operating

-25 .. 60°C

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

8kV

Release characteristic

C

Number of poles (total)

2

Number of protected poles

2

Rated current

16A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated voltage

400V

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.