Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current32A
Rated voltage400V
Number of protected poles2
Release characteristicD
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Number of poles (total)2
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Current limiting class3
Frequency50 - 60Hz
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 60°C
Built-in depth82.5mm
Connectable conductor cross section solid-core0 - 50mm²
Width in number of modular spacings3
Connectable conductor cross section multi-wired0 - 70mm²
Pollution degree3
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R0321 | S802S-D32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

32A

Rated voltage

400V

Number of protected poles

2

Release characteristic

D

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Number of poles (total)

2

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Suitable for flush-mounted installation

Additional equipment possible

Current limiting class

3

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Built-in depth

82.5mm

Connectable conductor cross section solid-core

0 .. 50mm²

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

0 .. 70mm²

Pollution degree

3

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.