  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Release characteristicD
Rated current40A
Number of poles (total)2
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Number of protected poles2
Pollution degree3
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Degree of protection (IP)IP20
Rated voltage400V
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0 - 70mm²
Current limiting class3
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Width in number of modular spacings3
Voltage typeAC
Connectable conductor cross section solid-core0 - 50mm²
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R0401 | S802S-D40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Release characteristic

D

Rated current

40A

Number of poles (total)

2

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Number of protected poles

2

Pollution degree

3

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Degree of protection (IP)

IP20

Rated voltage

400V

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 70mm²

Current limiting class

3

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Width in number of modular spacings

3

Voltage type

AC

Connectable conductor cross section solid-core

0 .. 50mm²

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA