Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Width in number of modular spacings3
Current limiting class3
Pollution degree3
Over voltage category3
Rated insulation voltage Ui690V
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Built-in depth82.5mm
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 50mm²
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp8kV
Additional equipment possibleYes
Release characteristicK
Number of poles (total)2
Rated current13A
Number of protected poles2
Voltage typeAC
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862001R0447 | S802S-K13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Width in number of modular spacings

3

Current limiting class

3

Pollution degree

3

Over voltage category

3

Rated insulation voltage Ui

690V

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Built-in depth

82.5mm

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 50mm²

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

8kV

Additional equipment possible

Release characteristic

K

Number of poles (total)

2

Rated current

13A

Number of protected poles

2

Voltage type

AC

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.